Component
Inner armor rods, outer armor rods, thimble, U-shaped hanging loop, extension loop, bolt, nut, etc.
Characteristic
1. Stress is distributed equally, without stress focus. It can protect optical cables very well.
2. Under the condition of not exceeding the intensity of cable’s side pressure, it has higher grip power for the cable, and can support higher tensile force.
3. The grip power for the cable is not less than 95% of rating’s pulling resisting intensity of the optical cable, completely satisfying the needs of setting up the cable.
2. Under the condition of not exceeding the intensity of cable’s side pressure, it has higher grip power for the cable, and can support higher tensile force.
3. The grip power for the cable is not less than 95% of rating’s pulling resisting intensity of the optical cable, completely satisfying the needs of setting up the cable.
Conditions for the usage
1. Terminal poles/towers;
2. Poles/towers with corner angles greater than 25°
3. Conjoint poles/towers of the optical cables or poles/towers with larger differences in terms of height.
2. Poles/towers with corner angles greater than 25°
3. Conjoint poles/towers of the optical cables or poles/towers with larger differences in terms of height.
Intensity
According to the requirement of customers, 30kN, 70kN, 100kN, 120kN, etc, can be supplied.
| ANZ cable dead end clamp | |||||||||
| Type | Cable Dia.(mm) | Holding strength(kn) | Span(m) | Length of outer(mm) | Length of endothecium(mm) | Weight(kg) | Universal scheme | ||
| Chevis (Eye chain link) | Thimble | Anchor shackle | |||||||
| ANZ 0940 020 | 8.6-9.4 | 20 | 200/300 | 800 | 1100 | 0.88 | ZH-7 | TC04 | U-7 |
| ANZ 1010 020 | 9.5-10.1 | 20 | 200/300 | 800 | 1100 | 1.02 | ZH-7 | TC04 | U-7 |
| ANZ 1070 020 | 10.2-10.7 | 20 | 200/300 | 800 | 1100 | 1.06 | ZH-7 | TC04 | U-7 |
| ANZ 1140 020 | 10.8-11.4 | 20 | 200/300 | 800 | 1100 | 1.08 | ZH-7 | TC04 | U-7 |
| ANZ 1220 020 | 11.5-12.2 | 20 | 200/300 | 800 | 1100 | 1.35 | ZH-7 | TC07 | U-7 |
| ANZ 1290 020 | 12.3-12.9 | 20 | 200/300 | 800 | 1100 | 1.38 | ZH-7 | TC07 | U-7 |
| ANZ 1370 020 | 13.0-13.7 | 20 | 200/300 | 800 | 1100 | 1.54 | ZH-7 | TC07 | U-7 |
| ANZ 1460 020 | 13.8-14.6 | 20 | 200/300 | 800 | 1100 | 1.57 | ZH-7 | TC07 | U-7 |
| ANZ 1550 020 | 14.7-15.5 | 20 | 200/300 | 800 | 1100 | 1.6 | ZH-7 | TC07 | U-7 |
| ANZ 0940 030 | 8.6-9.4 | 30 | 300/400 | 1100 | 1400 | 1.17 | ZH-7 | TC07 | U-7 |
| ANZ 1010 030 | 9.5-10.1 | 30 | 300/400 | 1100 | 1400 | 1.35 | ZH-7 | TC07 | U-7 |
| ANZ 1070 030 | 10.2-10.7 | 30 | 300/400 | 1100 | 1400 | 1.4 | ZH-7 | TC07 | U-7 |
| ANZ 1140 030 | 10.8-11.4 | 30 | 300/400 | 1100 | 1400 | 1.43 | ZH-7 | TC07 | U-7 |
| ANZ 1220 030 | 11.5-12.2 | 30 | 300/400 | 1100 | 1400 | 1.8 | ZH-7 | TC07 | U-7 |
| ANZ 1290 030 | 12.3-12.9 | 30 | 300/400 | 1100 | 1400 | 1.84 | ZH-7 | TC07 | U-7 |
| ANZ 1370 030 | 13.0-13.7 | 30 | 300/400 | 1100 | 1400 | 2.04 | ZH-7 | TC07 | U-7 |
| ANZ 1460 030 | 13.8-14.6 | 30 | 300/400 | 1100 | 1400 | 2.08 | ZH-7 | TC07 | U-7 |
| ANZ 1550 030 | 14.7-15.5 | 30 | 300/400 | 1100 | 1400 | 2.12 | ZH-7 | TC07 | U-7 |
| ANZ 1220 040 | 11.5-12.2 | 40 | 400/500 | 1260 | 1800 | 2.14 | PD-7 | TC07 | U-7/2 |
| ANZ 1290 040 | 12.3-12.9 | 40 | 400/500 | 1260 | 1800 | 2.19 | PD-7 | TC07 | U-7/2 |
| ANZ 1370 050 | 13.0-13.7 | 40 | 400/500 | 1260 | 1800 | 2.44 | PD-7 | TC07 | U-7/2 |
| ANZ 1460 040 | 13.8-14.6 | 40 | 400/500 | 1260 | 1800 | 2.49 | PD-7 | TC07 | U-7/2 |
| ANZ 1550 040 | 14.7-15.5 | 40 | 400/500 | 1260 | 1800 | 2.54 | PD-7 | TC07 | U-7/2 |
| ANZ 1650 040 | 15.6-16.5 | 40 | 400/500 | 1260 | 1800 | 2.92 | PD-7 | TC07 | U-7/2 |
| ANZ 1370 050 | 13.0-13.7 | 50 | 500/600/700 | 1400 | 2000 | 2.7 | PD-7 | TC07 | U-7/2 |
| ANZ 1460 050 | 13.8-14.6 | 50 | 500/600/700 | 1400 | 2000 | 2.76 | PD-7 | TC07 | U-7/2 |
| ANZ 1550 050 | 14.7-15.5 | 50 | 500/600/700 | 1400 | 2000 | 2.81 | PD-7 | TC07 | U-7/2 |
| ANZ 1650 050 | 15.6-16.5 | 50 | 500/600/700 | 1400 | 2000 | 3.23 | PD-7 | TC07 | U-7/2 |
| ANZ 1370 060 | 13.0-13.7 | 60 | 600/700/800 | 1560 | 2200 | 2.98 | PD-7 | TC07 | U-7/2 |
| ANZ 1460 060 | 13.8-14.6 | 60 | 600/700/800 | 1560 | 2200 | 3.04 | PD-7 | TC07 | U-7/2 |
| ANZ 1550 060 | 14.7-15.5 | 60 | 600/700/800 | 1560 | 2200 | 3.11 | PD-7 | TC07 | U-7/2 |
| ANZ 1650 060 | 15.6-16.5 | 60 | 600/700/800 | 1560 | 2200 | 3.57 | PD-7 | TC07 | U-7/2 |
| ANZ 1460 070 | 13.8-14.6 | 70 | 700/800/900 | 1600 | 2400 | 3.2 | PD-7 | TC07 | U-7/2 |
| ANZ 1550 070 | 14.7-15.5 | 70 | 700/800/900 | 1600 | 2400 | 3.27 | PD-7 | TC07 | U-7/2 |
| ANZ 1650 070 | 15.6-16.5 | 70 | 700/800/900 | 1600 | 2400 | 3.77 | PD-7 | TC07 | U-7/2 |
| ANZ 1750 070 | 16.6-17.5 | 70 | 700/800/900 | 1600 | 2400 | 4.12 | PD-7 | TC07 | U-7/2 |
| ANZ 1870 070 | 17.6-18.7 | 70 | 700/800/900 | 1600 | 2400 | 4.64 | PD-7 | TC07 | U-7/2 |
| ANZ 1550 080 | 14.7-15.5 | 80 | 800/900/1000 | 2000 | 3000 | 4.08 | PD-10 | TC-10 | U-10/2 |
| ANZ 1650 080 | 15.6-16.5 | 80 | 800/900/1000 | 2000 | 3000 | 4.71 | PD-10 | TC-10 | U-10/2 |
| ANZ 1750 080 | 16.6-17.5 | 80 | 800/900/1000 | 2000 | 3000 | 5.14 | PD-10 | TC-10 | U-10/2 |
| ANZ 1870 080 | 17.6-18.7 | 80 | 800/900/1000 | 2000 | 3000 | 5.79 | PD-10 | TC-10 | U-10/2 |
| ANZ 1650 100 | 15.6-16.5 | 100 | 1000 | 2800 | 4000 | 7.02 | PD-10 | TC-10 | U-10/2 |
| ANZ 1750 100 | 16.6-17.5 | 100 | 1000 | 2800 | 4000 | 7.22 | PD-10 | TC-10 | U-10/2 |
| ANZ 1870 100 | 17.6-18.7 | 100 | 1000 | 2800 | 4000 | 7.91 | PD-10 | TC-10 | U-10/2 |
Send Your Inquiry
Related Products
-

Preformed dead end guy grip
Ground wire for steel conductor; wire clamp is used for galvanized steel. Aluminum-clad steel, good ...
阅读更多 -

Preformed guy grip with dead end clamp
The preformed tension set is widely used for the installation of bare conductors or overhead insulat...
-

FDY Vibration damper
Clamp Type Vibration Damper for ADSS/OPGW cables, withtuning fork structure of Damper Weight, is val...
-

Preformed Dead End Guy Grip
Preformed Tension Clamp are designed to connect ADSS cables and poles/towers . Armor rods can provid...